LEX15
LEX15 Ex e certified resistance thermometer with cable for zone 1 and 2
Specifications
ATEX execution | ll 2 G Ex eb llC T6...T1 Gb |
ATEX certificate | DEKRA 17ATEX0123 X |
IECEx execution | Ex eb IIC T6...T1 Gb |
IECEx certificate | IECEx DEK 17.0046X |
Suitable for zone | 1 and 2 |
Ingress protection | IP65 / IEC529 |
Ambient temp. range | -45°C...+80°C, this can be limited depending on the materials applied such as cable, connection head or junction box. |
Construction | Mineral insulated (MgO) |
Material | SS316 standard, other materials possible |
Diameter | Customer to specify |
Length | Customer to specify |
Execution | Single or Duplex Pt100 |
Connection | 3-wire standard, 4-wire optional |
Accuracy | According IEC 60751 Cl. B, A or AA |
Measuring range | -20°C...+400°C standard, -220°C...+600°C optional |
Length | 45mm |
Diameter | To suit cable diameter |
Insulation | PVC standard, other materials possible |
Cable length | Customer to specify |
Option | PUR, Silicone or PTFE insulated cable |
Customisation possibilities
You can remark the customisation in your quote
Productcode | LEX15 |
---|---|
Sensor S or D | … |
Connection 3- or 4-wire | … |
Class B, A or AA | … |
Diameter | … |
Length "L"in mm | … |
Length "K" in mm | … |