DWR 6130
DWR 6130 Vibration proof resistance thermometer
Specifications
Designed for heavy duty marine applications | |
Type Approval | LLoyds Register Marine |
Category | LV2000 range |
Construction | Closed-end tube |
Material | SS 316 - (Wst 1.4401) standard, other materials possible |
Insertion length | 100mm standard, other lengths possible |
Process connection | 1/2" NPT, 3/4" NPT, 1/2" BSP or M20x1.5 |
Extension length | 100mm standard, other lengths possible |
Material | Aluminium, plastic or stainless steel |
Cable entry | M20x1.5 cable gland standard, other threads possible |
Type | MI 6140 |
Construction | Springloaded and replaceable |
Diameter | 6.0mm standard, other diameters possible |
Length | E = L + X + 35 mm |
Material | SS 316 - (Wst 1.4401) standard, other materials possible |
Insulation | Mineral insulated MgO |
Single or Duplex Pt100 | |
Style / Connection | 3-wire system standard, 4-wire system optional |
Accuracy | According IEC 60751 class B |
Range | -220 / +600°C |
Testing | Tested 200 Volt @ 20°C |
Insulation | Minimum 100 M ohm |
Transmitter 4-20mA | In-Head transmitter, standard or Ex version. Please select from our standard range or specify your own standard |
Swing-Cover head | DAN, transmitter direct mounted on measuring insert |
High Swing-Cover head | DAN-H, transmitter in cover, insert with ceramic block |
Customisation possibilities
You can remark the customisation in your quote
Productcode | DWR 6130 |
---|---|
Sensor ( S of D ) | … |
Length "L" in mm | … |
Lengte "X" in mm | … |