CA 1007
CA 1007 Gas and air temperature thermocouple
Specifications
Construction | Open-end perforated tube |
Material | SS 316 - (Wst 1.4401) |
Insert diameter | 9.0mm standard, other diameters possible |
Insertion length | Customer to specify |
Process connection | 1/2"BSP (G1/2"), 1/2"NPT, M20x1.5 or other threads possible |
Material | Aluminium, plastic or stainless steel |
Cable entry | M20x1.5 cable gland standard, other threads possible |
Type | MI 1025 |
Construction | Replaceable |
Diameter | 6 mm- tip open |
Length | E = L + 40 mm |
Material | SS 316 - (Wst 1.14401) |
Calibration | K, T, J, E, N, U or L |
For duplex | KK, TT, JJ, EE, NN, UU or LL |
Accuracy | According IEC 60584 |
Transmitter 4-20mA | In-Head transmitter, standard or Ex version. Please select from our standard range or specify your own standard |
High Swing-Cover head | DAN-H, transmitter in cover, insert with ceramic block |
Customisation possibilities
You can remark the customisation in your quote
Productcode | CA 1007 |
---|---|
Calibration | … |
Insertion length "L" mm | … |