RTX 6060
RTX 6060 RTD with integrated transmitter
Specifications
| Construction | Closed end tube with welded bottom. Liquid and gas tight. |
| Material | SS 316Ti - (Wst 1.4571) standard, other materials possible |
| Insertion length | Min. 40mm, max. 1000mm , to be specified |
| Diameter | 3.0 mm or 6.0 mm standard, other diameters possible |
| Ingress protection | IP 67 according to DIN 60529 when plugged in |
| Process pressure max. | 100 bar (at L= 100mm / +20°) |
| Response time | T50 = <1.0 s; T90 = <2,0 s depending on the process connection) |
| Screwed | 1/4"NPT, 1/2" NPT, 3/4" NPT, 1/4"BSP, 1/2" BSP or M20x1.5 |
| Flanged | Flanged TRI-CLAMP®, Micro-Clamp Tri-Clamp, Milk coupling DIN 11851 or Varivent® |
| Measuring range | To be specified |
| Sensor break detection | Upscale or downscale, to be specified |
| Sensor type | Single Pt100 |
| Connection | 2- or 3-wire system |
| Sensor limit (standard) | -30 / +300°C other limit can be specified (transmitter part 85°C max.) |
| Sensor accuracy | According to IEC 60751 Cl. B or A |
| Output | Loop powered 4-20mA at 8 - 35Vdc, M12 connector, 4 pins |
| Transmitter measuring range | -200 / 650°C, min span 40°C |
Customisation possibilities
You can remark the customisation in your quote
| Productcode | RTX 6060 |
|---|---|
| Pt100 or Pt1000 | … |
| Diameter | … |
| Insertion length in mm | … |
| Process connection | … |
| Transmitter range | … |
| Upscale or downscale sensor detection | … |