LEX15
LEX15 Ex e certified thermocouple with cable for zone 1 and 2
Specifications
| ATEX execution | II 2 G Ex eb IIC T6...T1 Gb |
| ATEX certificate | DEKRA 17ATEX0123 X |
| IECEx execution | Ex eb IIC T6...T1 Gb |
| IECEx certificate | IECEx DEK 17.0046X |
| Suitable for zone | 1 and 2 |
| Ingress protection | IP65 / IEC529 |
| Ambient temp. range | -45°C...+80°C, this can be limited depending on the materials applied such as cable, connection head or junction box. |
| Construction | Mineral insulated (MgO) |
| Material | SS316 standard, other materials possible |
| Diameter | Customer to specify (0.25-12.7mm) |
| Length | Customer to specify |
| Isolated |
| Length | 45 mm |
| Diameter | To suit cable diameter |
| Type of cable | PVC standard |
| Option | PUR, Silicon or PTFE insulated cable |
| Cable length | Customer to specify |
| Calibration | K, T, J, E, N, R, S, B, U or L |
| For duplex | KK, TT, JJ, EE, NN, RR, SS, BB, UU or LL |
| Accuracy | According to IEC 60584-1 |
| This datasheet is purely indicative, build-up of model code may vary from this datasheet depending on chosen model or execution! |
Customisation possibilities
You can remark the customisation in your quote
| Productcode | LEX15 |
|---|---|
| Thermocouple calibration | … |
| Colourcode | … |
| Diameter "D" | … |
| Length "L" in mm | … |
| Length "K" in mm | … |