HT 4090
HT 4090 Glass industry Single or Tri-level thermocouple
Specifications
| Construction | Platinum Rhodium tip suitable for molten glass |
| Support tube | Ceramic 710 (C799), 24x18mm |
| Insertion length | 1000mm standard, other lengths possible |
| Standard | PtRh10% |
| Optional | Oxide Dispersion Strengthened, ODS® Platinum |
| Diameter tip | 9.0x1.0mm standard, other diameters possible |
| Tip length | Customer to specify |
| Temperature | 1800°C maximum |
| Material | Aluminium or Stainless Steel |
| Cable entry | M20x1.5 standard, other threads possible |
| Flange | According to ANSI or DIN standard, to specify |
| Material | To specify |
| Single thermocouple | R, S or B |
| Tri-level thermocouple | Type B standard |
| Wire grade | Type R/S available in HTX grade |
| Wire size | 0.35mm or 0.5mm |
| Accuracy | According IEC 60584-1 |
| Improved wire option | HTX grade for R and S |
| Transmitter 4-20mA | In-Head transmitter, standard or Ex version. Please select from our standard range or specify your own standard |
| Swing-Cover head | DAN, transmitter direct mounted on measuring insert |
| High Swing-Cover head | DAN-H, transmitter in cover, insert with ceramic block |
Customisation possibilities
You can remark the customisation in your quote
| Productcode | HT 4090 |
|---|---|
| Calibration | … |
| Length "L" in mm | … |
| Wire size | … |
| Single (S) or Tri-level (T) thermokoppel | … |
| Options | … |