DWR 6060 Bearing Resistance Thermometer


Design
Designed for use on ships
Sheath
Construction Mineral insulated
Material SS 316 - ( Wst 1.4401 )
Diameter "D" 3 mm
Length "L" Customer to specify
Process connection 2 compressionglands 1 / 4" NPT
Lead wire
Silicon insulated flexible copper wire with silicon outer jacket 240 °C
Lead wire length "K" Customer to specify
Sensor
Single Pt 100
Accuracy According IEC 751 class B
Connection 3 wire system ( Optional 4 wire system )
Range -100 to +250 °C
Testing Tested at 200 Volt / 20 °C
Insulation Minimum 100 M ohm
Ordering code  
Model   DWR 6060    
       
Length "L" in mm    
Length "K" in mm    


 