CA 1021 Heavy Duty Thermocouple for Thermowell Mounting


Connection head
Model CE
Material Cast aluminium
Cable entry M20x1.5 Female thread other optional
Ingress protection IP65 / IEC529
Sensing element
Type MI 1025
Construction Replaceable springloaded
Diameter 6 mm
Length "E" E = U + X + 40 mm
Material SS 316 - (Wst 1.4401)
Element
Calibration K, T, J, E, N, U or L
For duplex KK, TT, JJ, EE, NN, UU or LL
Accuracy According IEC 584-1 / DIN 43710
Hot junction Insulated
Extension
Type Nipple - union – nipple
Material Galvanized carbonsteel or SS316
Connection 1 / 2" NPT male thread
Length "X" 130 mm standard, other length possible
Options
Transmitter 4-20mA In-Head Transmitter, standard or ATEX Explosion proof.
Please select from our standard range, see "transmitter"
chapter, specify make, model and range.
Swing-Cover head DAN. Transmitter direct mounted on measuring insert.
High Swing-Cover head DAN-H. Transmitter in cover. Insert with ceramic block.
Ordering code  
Model   CA 1021    
       
Calibration    
length "U" in mm    


 