DWK 6010 Vibration Proof Thermocouple


Design
Application Designed for use on combustion engines
Protection tube
Construction Closed-end tube
Material SS 316 - ( Wst 1.4401 )
Insertion length "L" Customer to specify, standard 150 mm
Diameter 8 mm
Process connection 1 / 4" BSP steel compression gland
Pocket / Thermowell
Small diameter sensors can break due to high vibrations, the use of a thermowell or pocket can be imperative, check with your engine manufacturer or consult factory.
Lead wire
Heat and oil resistant, armoured extention cable 250 °C
Lead wire length "K"
Customer to specify, standard 1000 mm
Element
Sensor K, J or L Thermocouple, Customer to specify
Accuracy According IEC 584-1
Testing Tested at 200 volt / 20 °C
Insulation Minimum 10 M ohm
Design Vibrationproof
Temperature
800 °C maximum
Ordering code  
Model   DWK 6010      
         
Thermocouple type     
Length "L" in mm     
Length "K" in mm     


 