CA 1005 Fast Response Thermocouple


Protection tube
Construction Closed-end tube
Material SS 316 - (Wst 1.4401)
Insertion length "L" Customer to specify
Process connection 1 / 2" BSP
Extension length "X" Customer to specify
Connection head
Model "B", according DIN 43729
Material Cast aluminium
Cable entry M20 x 1.5 cable gland
Sensing element
Construction Fixed
Tip Reduced diameter
Stem diameter 9 mm
Tip diameter 6 mm
Element
Calibration K, T, J, E, N, U or L
For duplex KK, TT, JJ, EE, NN, UU or LL
Accuracy According IEC 584-1 / DIN 43710
Options
Transmitter 4-20mA In-Head Transmitter, standard or ATEX Explosion proof.
Please select from our standard range, see "transmitter"
chapter, specify make, model and range.
Swing-Cover head DAN. Transmitter direct mounted on measuring insert.
High Swing-Cover head DAN-H. Transmitter in cover. Insert with ceramic block.
Ordering code  
Model   CA 1005      
         
Calibration     
Insertion length "L" in mm     
Extension length "X" in mm     


 
Back to top Back Email page Download PDF search Sitemap Conditions of Purchase
©2003 - 2008 ThermoThermo-Electra BVWeteringweg 102641 KM PijnackerT +31 (0)15 362 12 00F +31 (0)15 369 40 82E info@thermo-electra.com