HT 4030 High Temperature Thermocouple up to 1450°C


Protection tube
Construction Gastight ceramic
Insertion length "L" Customer to specify
Diameter 10 x 2 mm
Material Ceramic 610 (C610)
Temperature 1450 °C maximum
Flange Model MFA-A
Connection head
Model "B", according DIN 43729
Material Cast aluminium
Cable entry M20x1.5 cable gland
Head extention Steel 15 mm
Sensing element
Insulation Ceramic rod
Element
Calibration B, R or S
For duplex BB, RR or SS
Wire size 0.35 or 0.5 mm Customer to specify
Accuracy According IEC 584-1 / DIN43710
Options
Connection head Other options possible
Transmitter 4-20 mA Please select from transmitter chapter
Ordering code  
Model   HT 4030      
         
Calibration     
Length "L" in mm     
Wire size     


 