LEX30 EEx d Thermocouple with Integrated 2-Wire Transmitter


Construction According EN 50014 and EN 50018
Ex execution II 2G Eex d IIC T6
Certificate ISSeP02ATEX012
Suitable for zone 1 and 2
Ingress protection IP66 / IEC529
Ambient temp. limits

-20°C...+65°C standard, -40°C...+65°C optional

Transmitter
Model and Type To be specified
Ambient temp. limits Depending on transmitter specs.
Connection head
Material Cast aluminium or SS316
Cable entry Single M20 x 1,5, two entries optional
Cover Threaded with retaining chain
Fire Lock At process side
Sensing element
Construction Replaceable, springloaded > 10 mm
Diameter 6.0 mm
Type Mineral insulated
Element
Calibration K, T, J, E, R, S, B, U, N or L
For duplex KK, TT, JJ, EE, RR, SS, BB, UU, NN or LL
Accuracy According IEC 584
Extension
Type Nipple - union - nipple
Material Stainless Steel 316
Connection 1/2" NPT male thread
Length "X" 150 mm standard Other length possible
Ordering code  
Model   LEX30    
       
Calibration    
Length "U" in mm    


 