DWR 6120 Vibration Proof Resistance Thermometer


Protection tube
Construction Closed-end tube
Material SS 316 - ( Wst 1.4401 )
Diameter Outer diameter 11mm, wall thickness 2mm
Insertion length "L" Customer to specify, standard 100 mm
Process connection 1 / 2" BSP
Connection head
Model "B", according DIN 43729
Material Cast aluminium
Cable entry M20 x 1.5 cable gland
Sensing element
Type MI 6140
Construction Replaceable springloaded
Diameter 6 mm
Length "E" E = L + 45 mm
Material SS 316 - ( Wst 1.4401 )
Insulation Mineral insulated MgO
Sensor
Single Pt 100 : "S"
Duplex Pt 100 : "D"
Accuracy According IEC 751 class B
Connection 3 wire system ( Optional 4 wire system )
Range -220 / +600 °C
Testing Tested at 200 Volt / 20 °C
Insulation Minimum 100 M ohm
Design Vibration : 2 to 25 Hz - 1.6 mm 25 to 5000 Hz - 4 g
Ordering code  
Model   DWR 6120    
       
Sensor ( S or D )    
Insertion length "L" in mm    


 
Back to top Back Email page Download PDF search Sitemap Conditions of Purchase