E 40S Round Silicone Thermocouple Extension Cable -60°C to 230°C


Specifications
Insulation material Each wire and overall jacket high quality Silicone rubber
Temperature limits -60 / +230 °C
Moisture resistance Good
Conductors
Conductor type Stranded, parallel conductors
Wire size 0.5 mm² ( 16 x 0.2 mm ) and 1.5 mm² ( 48 x 0.2 mm )
Calibration
Thermocouple type K, T, J, E, U, L, N, B, R or S
Limits of error Conforms to IEC 584 and ANSI MC 96.1
Colour code
According thermocouple calibration
IEC 584 or ANSI MC96.1
Applications
High temperature circuits
Testing
Heat treatment
General Industry
Dimensions
Conductor size 0.5 1.5 mm²
Outside diameter 4.0 7.0 mm
Weight 25 100 kg/km
Ordering code  
Model   E 40S      
         
Conductor size     
Calibration     
Colour code ( IEC / ANSI )     


 